Home / Learn / Glossary / SIL (Safety Integrity Level)

SIL (Safety Integrity Level)

Measure

Topic overview

A discrete level (SIL 1 to SIL 4) specifying the required risk reduction and dependability of a safety function under and its sector standards.

Quick facts

Defined byIEC 61508
RangeSIL 1 (lowest) to SIL 4 (highest)
Applies toIndividual safety functions, not products
High demand metricPFH (probability of dangerous failure per hour)
Low demand metricPFDavg (average probability of failure on demand)
Also requiresSystematic capability and architectural constraints

SIL applies to safety functions, not products or companies. A statement like 'our robot is SIL 2' is technically meaningless; the correct claim is that a specific function, such as safe speed monitoring, achieves SIL 2.

A higher SIL requires lower probability of dangerous failure and stricter development processes: SIL 2 in high-demand mode requires a probability of dangerous failure per hour better than 1E-6, SIL 3 better than 1E-7, with each level also raising expectations for architecture, diagnostics, and systematic techniques.

Each sector adapts the scale. Rail software uses Software SIL 0 to 4 under ; machinery typically targets SIL 1 to 3 under , since SIL 4 is generally reserved for process and rail applications with catastrophic multi-fatality potential.

The automotive analog is (A to D) under , and machinery control systems may instead use Performance Levels (PL a to e) under ISO 13849. Cross-mapping between these scales is approximate and should be done through the standards' published comparison tables, not by intuition.

Achieving a SIL requires satisfying three parallel constraints: the probabilistic hardware target, architectural constraints (hardware fault tolerance and safe failure fraction, or the route 2H alternative), and systematic capability of the development process. Meeting the failure-rate math alone is never sufficient.

SIL targets, high demand mode (PFH)

SIL 11E-6 to <1E-5 /h
SIL 21E-7 to <1E-6 /h
SIL 31E-8 to <1E-7 /h
SIL 41E-9 to <1E-8 /h

Why SIL matters to your program

The SIL target set at risk assessment time is the single largest cost driver in a safety program. Each level step roughly translates into more redundancy, more diagnostics, more process rigor, and more independent verification, so an over-assigned SIL wastes budget while an under-assigned one fails assessment or, worse, ships inadequate risk reduction.

Customers and integrators specify SIL in procurement contracts, so the level a component or subsystem can credibly claim directly sets which markets and tenders are accessible.

Working with SIL

How a SIL target is met

Risk analysisDetermine required risk reduction per function
SIL allocationAssign SIL target to each safety function
ArchitectureMeet hardware fault tolerance and SFF constraints
QuantifyFMEDA yields PFH/PFD against the target band
SystematicApply lifecycle techniques for the SIL
AssessIndependent assessment confirms the claim

Common SIL mistakes

Claiming a SIL for a product or company rather than a named safety function.
Averaging or mixing SIL and PL scales informally instead of using the standards' mapping tables.
Meeting the PFH number while ignoring architectural constraints or systematic capability, all three of which are mandatory.
Using optimistic component failure rates without source justification.
Assuming a SIL-certified PLC makes the application program safe, when application software has its own requirements under the standards.

Standards related to SIL

IEC 61508 Functional Safety of E/E/PE Safety-Related Systems

SIL is defined and governed by IEC 61508 - the umbrella functional safety standard defining the safety lifecycle, sil levels, and requirements for electrical, electronic, and programmable systems.

EN 50128 Railway Software

SIL is defined and governed by EN 50128 - software for railway control and protection systems, defining software sil requirements and lifecycle.

IEC 62061 Safety of Machinery - Functional Safety of Control Systems

Assessors evaluate SIL against IEC 62061, machinery-sector implementation of iec 61508 for safety-related electrical control systems.

Cross-sector integrity alignment (approximate)

IEC 61508 SILISO 13849 PLISO 26262 ASILEN 50128 SW-SIL
SIL 1PL b / PL cASIL A / BSIL 1
SIL 2PL dASIL B / CSIL 2
SIL 3PL eASIL DSIL 3
SIL 4no equivalentno equivalentSIL 4

SIL by industry

Industrial Machinery

SIL shapes how industrial machinery teams argue safety - fixed and mobile machinery, packaging lines, and manufacturing equipment.

Rail & Transit

In rail & transit, SIL comes up in nearly every certification conversation: freight and passenger rail signaling, train control, and transit systems.

Ask our team about SIL

SIL: related terms

How each connects to SIL:

Performance Level (PL) Measure

Performance Level is the natural next concept after SIL; assessors expect teams to connect the two.

ASIL Measure

ASIL is the natural next concept after SIL; assessors expect teams to connect the two.

PFH Measure

PFH is the natural next concept after SIL; assessors expect teams to connect the two.

Functional Safety Concept

IEC 61508 connects the two: SIL and Functional Safety are assessed against the same lifecycle.

Safety Function Concept

Safety Function is governed by IEC 61508 as well, which is why the two show up together in audits.

Safe Torque Off (STO) Safety function

IEC 61508 connects the two: SIL and Safe Torque Off are assessed against the same lifecycle.

FMEA Artifact

FMEA is governed by IEC 61508 as well, which is why the two show up together in audits.

FMEDA Artifact

Both SIL and FMEDA sit under IEC 61508, so evidence for one usually references the other.

Fault Tree Analysis Artifact

Both SIL and Fault Tree Analysis sit under IEC 61508, so evidence for one usually references the other.

CENELEC Rail Standards Concept

CENELEC Rail Standards is governed by EN 50128 as well, which is why the two show up together in audits.

Verification and Validation (V&V) Activity

Verification and Validation is governed by IEC 61508 as well, which is why the two show up together in audits.

Safety Management System (SMS) Process

IEC 61508 connects the two: SIL and Safety Management System are assessed against the same lifecycle.

CSA services for SIL

How each service connects to SIL.

Gap Analysis
Rapid Safety Diagnostic

Rapid Safety Diagnostic benchmarks your current handling of SIL against the standards that govern it.

Onsite Safety Review

Onsite Safety Review shows where your SIL evidence stands before an assessor looks: two days onsite with your team and equipment: walkdowns, interviews, and a readout of observed gaps against applicable standards.

Functional Safety Gap Analysis & Roadmap

Functional Safety Gap Analysis & Roadmap shows where your SIL evidence stands before an assessor looks: structured assessment of your current safety lifecycle and evidence against target standards, delivering a certification roadmap with effort estimates.

Safety Engineering
Risk Assessment

Risk Assessment produces and defends the work products where SIL lives: a complete iso 12100 or sector-appropriate risk assessment with one stakeholder review cycle, producing the documented basis for your safety concept.

SMS Stand-Up

In SMS Stand-Up, CSA engineers execute SIL work inside your program - templates, processes, procedures, and training to establish a complete safety management system, including qms integration.

Product Certification Management

In Product Certification Management, CSA engineers execute SIL work inside your program - a csa safety manager runs your certification program end to end: planning, evidence management, assessor liaison, and closure.

Safety Program & Certification Support

Safety Program & Certification Support turns SIL from a requirement into reviewed, assessor-ready evidence.

Safety Case Maintenance

Safety Case Maintenance produces and defends the work products where SIL lives: ongoing stewardship of your certified safety case: change impact analysis, evidence updates, and periodic assessor reviews.

Embedded Engineering Program

Embedded Engineering Program produces and defends the work products where SIL lives: dedicated csa functional safety engineers embedded in your team, managed by csa, delivering inside your development process.

Training
Custom Safety Training

Teams leave Custom Safety Training able to apply SIL on their own program, not just define it.

Private Safety Training

Private Safety Training builds your team's working command of SIL - the full four-day csa certification training delivered privately for up to eight participants at your site or remotely.

Advisory
On-Demand Advisory

On-Demand Advisory gives you a senior sounding board for SIL decisions - twelve 30-minute expert calls on a monthly cadence.

Fractional Safety Manager

Fractional Safety Manager keeps SIL strategy on track between major program milestones.